Radar level transmitter manufacturer with Kaidi86: The third case is that, during the commissioning stage of a platform construction, when the liquid level is higher than 3800mm, the radar level meter of the dirty oil tank will frequently jump to 0mm, which leads to the shutdown of the fourth-stage production unit. After on-site inspection, the power supply voltage of the radar level meter transmitter is only 9.5V, which is lower than the working power supply voltage of the radar level meter. By further searching for the cause of the failure, found that when the high liquid level, the voltage at the power supply is 23.7V, the safety gate output drops to 9.7V, judged as a safety gate transmitter failure. After replacing the safety grid, the voltage returns to normal, the cabin radar level meter in the test to rule out the problem. See even more details on radar level transmitter.
Effective Echo Management- Pulse radar technology generates echoes at certain time intervals. This feature enables radar sensors to handle echoes and distinguish echoes. A common occurrence in complex process vessels and solid material silos. This capability greatly enhances the accuracy of measurements in situations where traditional methods may struggle. The versatility and dependability of radar level measurement make it suitable for a range of applications. Here are some important areas where radar sensors excel- Process Tanks-In industries, radar level sensors are deployed to monitor levels in process tanks. Whether its chemicals, petroleum products or water treatment facilities radar sensors provide real time data to optimize process control. Storage Tanks- Large scale storage tanks require precise level monitoring to efficiently manage inventory and prevent overfilling or underfilling. Radar sensors are the trusted choice for maintaining inventory balance.
If the radar level meter is unreasonably selected, the interference echo cannot be handled well, and the reliability of the instrument will be reduced. Therefore, the following factors should be considered when selecting a radar level meter: Conductivity and dielectric constant of the measured medium. The measured medium is a conductive liquid or a liquid with a dielectric constant above 4. Generally, a common radar is selected. Liquids with small dielectric constants (dielectric constants below 2) and some conductive solids often use precision radars or guided wave radars due to the large amount of interference echoes.
With the continuous advancement of science and technology, radar water level meters have been used more and more. It has the advantages of low cost, high stability, flexibility, high reliability, low power consumption, convenient parameter setting, safe and simple maintenance, etc., and has important promotion value. Today, the editor will take you to a simple understanding of radar water level meter. Radar water level meter is a kind of measurement equipment introduced from abroad in recent years. The water level meter has mature technology, high measurement accuracy, easy installation, and is not restricted by environment and geography, so it has been widely used.
An important part of steam generation is the quality of the steam generated. Maintaining water quality in the boiler within design parameters ensures the highest quality steam possible while minimizing blowdown of the boiler, both of which improve energy and resource management. Continuous or manual blowdown of the boiler minimizes scale accumulation and corrosion resulting from impurities in the water. The blowdown provides a means of accommodating liquid and impurities from the boiler, with the latter facilitating energy recovery through the use of flash steam.
Secondly, in cement production, material level measurement encountered another difficulty is strong dust interference, especially pneumatic conveying powder silo, dust flying when feeding, low visibility, laser level meter and high energy ultrasonic level meter can not be measured, although radar level meter at this time can receive part of the surface echo. But the echo signal was also weakened. In addition, due to the uneven surface of the radar echo is refracted, will also lead to the existence of radar echo; In addition, there are some conditions from the bottom to the bin inflation, so that the material surface loose, material level measurement is more difficult.
KAIDI level transmitter manufacturer is dedicated in providing complete customized solutions for a wide range of industrial automation process applications – in material level, liquid flow, pressure and temperature. We are constantly developing and innovating, our core vision – “to provide solutions that exceed customers’ expectations. In 2012, the company successfully expanded its operations both locally and internationally, achieving global success and recognition for quality fork type level switch, magnetic level gauge products and services. See additional info at kaidi86.com. Our Radar Level Meter has a range of up to 150 meters, frequency up to 120GHz and an accuracy of ±1mm, which can cope with various complex measurement conditions.
The interference comes not only from the outside, but also from the inside of the radar level gauge, such as interference caused by wires, inductance and capacitance between the power transformer and electronic components. In addition, the internal components can also generate noise interference. Today, most radar level gauges have also begun to be improved, using high-frequency microwave technology, which greatly improves the performance of the level gauge and reduces interference.
When the distance between the liquid level of the measured medium and the electromagnetic wave transmitter is less than 4m, the guided wave radar is selected. If the distance between the liquid level of the measured medium and the electromagnetic wave transmitter is greater than 4m and less than 35m, select the guided wave radar with the guided wave cable. When the distance between the liquid level of the measuring medium and the electromagnetic wave transmitter is greater than 35m, or when the liquid level of the measuring medium is high temperature, high viscosity or solid liquid level, the air-shooting radar should be selected.
Product features: The gas display is red and the liquid display is green, the luminous display is clear, the observation is large, and the visual distance is long. The liquid level sensor can be clearly displayed by red and green light column, which is suitable for application in dark places and more eye-catching at night. The body is made of stainless steel, the level meter display device does not contact the medium in the container, and there is no leakage. Suitable for first, second and third class containers, suitable for containers containing flammable, toxic and corrosive media.